Overview
Harsh industrial problems require rugged solutions. The TNE-03 provides power and environmental protection for up to 3 FiberPlex ‘TD Series’ of fiber optic modules (includes TD and TIS models). Convenient DIN rail mounting provides a simple and easy installation for TD Series modules when used with the TD-DINR DIN rail adapters. An 18W 12V power supply comes standard. For light pole installations and other applications where industrial lighting voltage (eg 277 VAC) is available, the TNE-03-T includes a 208/277/380 VAC step-down transformer pre-installed. The enclosure carries a full NEMA 4x rating and is ready to be punched to accommodate your connectivity needs. Environmentally sealed conduit connectors must be used to maintain seal. TNE-03-HV Shown with included Transformer and TD Modules sold separately
Features:
- NEMA 4x Rated
- Provides mounting and power for up to 3 single wide TD Series modules, or 1 double wide module
- Securely seats modules with TD-DINR mounting clips for DIN rail
- DIN rail power supply included
- Optional step-down transformer accepts 208/277/380 VAC industrial power
Applications:
- Security Cameras (IP or SDI)
- Harsh Environment Communications
- Mass Notification
- Transportation
PHYSICAL SPECIFICATIONS |
|
Length |
Width |
Height |
Weight |
Case Dimensions (Unloaded) |
13.5 in (343 mm) |
11.4 in (291 mm) |
5.7 in (144 mm) |
11.25 lb (5.1 kg) |
Case Dimensions with High Voltage Option (Unloaded) |
13.5 in (343 mm) |
11.4 in (291 mm) |
5.7 in (144 mm) |
7.71 lb (3.5 kg) |
ELECTRICAL SPECIFICATIONS |
|
Min |
Typ |
Max |
Units |
Power Requirement |
Voltage Range |
100 |
110 |
240 |
VAC |
Voltage Range (HV option) |
- |
208/277/ 380 |
- |
VAC |
Power Line Frequency |
50 |
- |
60 |
Hz |
Power Consumption |
- |
18 |
- |
W |
TNE-03 |
Standard 110-240V AC supply |
TNE-03-HV |
Includes step-down transformer |
This product has no accessories